<LOGO>
FM Transmitter Measurement Report
Created: 2024-08-21 11-28-55
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.30 MHz 5/5, 72 dBuV NOSTALGI
Pilot RDS Phase Difference
6.1 kHz 3.0 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
8 kHz 65 kHz 11046 0,0272
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,3 dBr 5,83 dBr 6,8 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"NOSTALGI" 6411 10 (Pop M) 1 0 1 7 --:--
RT
"Queen - Somebody to love "
AF EON
92.7, 94.3, 99.5, 100.5 MHz -
FM Scope Max at: 65 kHz MIN: 8 kHz % above 76 kHz: 0,0272 Acquired: 2024/08/21 11.27.50 Total samples: 11046 Equivalent time: 0:09:12 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 6,8 dBr MIN: 4,3 dBr AVE: 5,83 dBr % above 12,2 dBr: 0,0 Last value: 5,4 dBr (2024/08/21 11.27.50) 11.14 11.16 11.18 11.20 11.22 11.24 11.26 0 2 4 6 Pm [dBr]